=head1 NAME gvpe.conf - configuration file for the GNU VPE daemon =head1 SYNOPSIS # global options for all nodes udp-port = 407 mtu = 1492 ifname = vpn0 # first node is named branch1 and is at 1.2.3.4 node = branch1 hostname = 1.2.3.4 # second node uses dns to resolve the address node = branch2 hostname = www.example.net udp-port = 500 # this host uses a different udp-port # third node has no fixed ip address node = branch3 connect = ondemand =head1 DESCRIPTION The gvpe config file consists of a series of lines that contain C pairs. Empty lines are ignored. Comments start with a C<#> and extend to the end of the line. They can be used on their own lines, or after any directives. Whitespace is allowed around the C<=> sign or after values, but not within the variable names or values themselves. All settings are applied "in order", that is, later settings of the same variable overwrite earlier ones. The only exceptions to the above are the "on" and "include" directives: =over 4 =item on nodename ... =item on !nodename ... You can prefix any configuration directive with C and a nodename. GVPE will will only "execute" it on the named node, or (if the nodename starts with C) on all nodes except the named one. Example: set the MTU to C<1450> everywhere, C to C on C, and C to C everywhere but on branch2. mtu = 1450 on branch1 loglevel = noise on !branch2 connect = ondemand =item include relative-or-absolute-path Reads the specified file (the path must not contain whitespace or C<=> characters) and evaluate all config directives in it as if they were spelled out in place of the C directive. The path is a printf format string, that is, you must escape any C<%> by doubling it, and you can have a single C<%s> inside, which will be replaced by the current nodename. Relative paths are interpreted relative to the GVPE config directory. Example: include the file F in the config directory on every node. include local.conf Example: include a file FnodenameF<.conf> include conf/%s.conf =back =head1 ANATOMY OF A CONFIG FILE Usually, a config file starts with a few global settings (like the UDP port to listen on), followed by node-specific sections that begin with a C line. Every node that is part of the network must have a section that starts with C. The number and order of the nodes is important and must be the same on all nodes. It is not uncommon for node sections to be completely empty - if the default values are right. Node-specific settings can be used at any time. If used before the first node section they will set the default values for all following nodes. =head1 CONFIG VARIABLES =head2 GLOBAL SETTINGS Global settings will affect the behaviour of the running gvpe daemon, that is, they are in some sense node-specific (config files can set different values on different nodes using C), but will affect the behaviour of the gvpe daemon and all connections it creates. =over 4 =item chroot = path or / Tells GVPE to chroot(2) to the specified path after reading all necessary files, binding to sockets and running the C script, but before running C or any other scripts. The special path F instructs GVPE to create (and remove) an empty temporary directory to use as new root. This is most secure, but makes it impossible to use any scripts other than the C one. =item chuid = numerical-uid =item chgid = numerical-gid These two options tell GVPE to change to the given user and/or group id after reading all necessary files, binding to sockets and running the C script. Other scripts, such as C, are run with the new user id or group id. =item chuser = username Alternative to C and C: Sets both C and C to the user and (primary) group ids of the specified user (for example, C). =item dns-forw-host = hostname/ip The DNS server to forward DNS requests to for the DNS tunnel protocol (default: C<127.0.0.1>, changing it is highly recommended). =item dns-forw-port = port-number The port where the C is to be contacted (default: C<53>, which is fine in most cases). =item dns-case-preserving = yes|true|on | no|false|off Sets whether the DNS transport forwarding server preserves case (DNS servers have to, but some access systems are even more broken than others) (default: true). Normally, when the forwarding server changes the case of domain names then GVPE will automatically set this to false. =item dns-max-outstanding = integer-number-of-requests The maximum number of outstanding DNS transport requests (default: C<100>). GVPE will never issue more requests then the given limit without receiving replies. In heavily overloaded situations it might help to set this to a low number (e.g. C<3> or even C<1>) to limit the number of parallel requests. The default should be working OK for most links. =item dns-overlap-factor = float The DNS transport uses the minimum request latency (B) seen during a connection as it's timing base. This factor (default: C<0.5>, must be > 0) is multiplied by B to get the maximum sending rate (= minimum send interval), i.e. a factor of C<1> means that a new request might be generated every B seconds, which means on average there should only ever be one outstanding request. A factor of C<0.5> means that GVPE will send requests twice as often as the minimum latency measured. For congested or picky DNS forwarders you could use a value nearer to or exceeding C<1>. The default should be working OK for most links. =item dns-send-interval = send-interval-in-seconds The minimum send interval (= maximum rate) that the DNS transport will use to send new DNS requests. GVPE will not exceed this rate even when the latency is very low. The default is C<0.01>, which means GVPE will not send more than 100 DNS requests per connection per second. For high-bandwidth links you could go lower, e.g. to C<0.001> or so. For congested or rate-limited links, you might want to go higher, say C<0.1>, C<0.2> or even higher. The default should be working OK for most links. =item dns-timeout-factor = float Factor to multiply the C (see C) by to get request timeouts. The default of C<8> means that the DNS transport will resend the request when no reply has been received for longer than eight times the minimum (= expected) latency, assuming the request or reply has been lost. For congested links a higher value might be necessary (e.g. C<30>). If the link is very stable lower values (e.g. C<2>) might work nicely. Values near or below C<1> makes no sense whatsoever. The default should be working OK for most links but will result in low throughput if packet loss is high. =item if-up = relative-or-absolute-path Sets the path of a script that should be called immediately after the network interface is initialized (but not necessarily up). The following environment variables are passed to it (the values are just examples). Variables that have the same value on all nodes: =over 4 =item CONFBASE=/etc/gvpe The configuration base directory. =item IFNAME=vpn0 The network interface to initialize. =item IFTYPE=native # or tincd =item IFSUBTYPE=linux # or freebsd, darwin etc.. The interface type (C or C) and the subtype (usually the OS name in lowercase) that this GVPE was configured for. Can be used to select the correct syntax to use for network-related commands. =item MTU=1436 The MTU to set the interface to. You can use lower values (if done consistently on all nodes), but this is usually either inefficient or simply ineffective. =item NODES=5 The number of nodes in this GVPE network. =back Variables that are node-specific and with values pertaining to the node running this GVPE: =over 4 =item IFUPDATA=string The value of the configuration directive C. =item MAC=fe:fd:80:00:00:01 The MAC address the network interface has to use. Might be used to initialize interfaces on platforms where GVPE does not do this automatically. Please see the C man page for platform-specific information. =item NODENAME=branch1 The nickname of the node. =item NODEID=1 The numerical node ID of the node running this instance of GVPE. The first node mentioned in the config file gets ID 1, the second ID 2 and so on. =back In addition, all node-specific variables (except C) will be available with a postfix of C<_nodeid>, which contains the value for that node, e.g. the C variable contains the MAC address of node #1, while the C variable contains the name of node #22. Here is a simple if-up script: #!/bin/sh ip link set $IFNAME up [ $NODENAME = branch1 ] && ip addr add 10.0.0.1 dev $IFNAME [ $NODENAME = branch2 ] && ip addr add 10.1.0.1 dev $IFNAME ip route add 10.0.0.0/8 dev $IFNAME More complicated examples (using routing to reduce ARP traffic) can be found in the F subdirectory of the distribution. =item ifname = devname Sets the tun interface name to the given name. The default is OS-specific and most probably something like C. =item ifpersist = yes|true|on | no|false|off Should the tun/tap device be made persistent, that is, should the device stay up even when gvpe exits? Some versions of the tunnel device have problems sending packets when gvpe is restarted in persistent mode, so if the connections can be established but you cannot send packets from the local node, try to set this to C and do an ifconfig down on the device. =item ip-proto = numerical-ip-protocol Sets the protocol number to be used for the rawip protocol. This is a global option because all nodes must use the same protocol, and since there are no port numbers, you cannot easily run more than one gvpe instance using the same protocol, nor can you share the protocol with other programs. The default is 47 (GRE), which has a good chance of tunneling through firewalls (but note that gvpe's rawip protocol is not GRE compatible). Other common choices are 50 (IPSEC, ESP), 51 (IPSEC, AH), 4 (IPIP tunnels) or 98 (ENCAP, rfc1241). Many versions of Linux seem to have a bug that causes them to reorder packets for some ip protocols (GRE, ESP) but not for others (AH), so choose wisely (that is, use 51, AH). =item http-proxy-host = hostname/ip The C family of options are only available if gvpe was compiled with the C<--enable-http-proxy> option and enable tunneling of tcp connections through a http proxy server. C and C should specify the hostname and port number of the proxy server. See C if your proxy requires authentication. Please note that gvpe will still try to resolve all hostnames in the configuration file, so if you are behind a proxy without access to a DNS server better use numerical IP addresses. To make best use of this option disable all protocols except TCP in your config file and make sure your routers (or all other nodes) are listening on a port that the proxy allows (443, https, is a common choice). If you have a router, connecting to it will suffice. Otherwise TCP must be enabled on all nodes. Example: http-proxy-host = proxy.example.com http-proxy-port = 3128 # 8080 is another common choice http-proxy-auth = schmorp:grumbeere =item http-proxy-port = proxy-tcp-port The port where your proxy server listens. =item http-proxy-auth = login:password The optional login and password used to authenticate to the proxy server, separated by a literal colon (C<:>). Only basic authentication is currently supported. =item keepalive = seconds Sets the keepalive probe interval in seconds (default: C<60>). After this many seconds of inactivity the daemon will start to send keepalive probe every 3 seconds until it receives a reply from the other end. If no reply is received within 15 seconds, the peer is considered unreachable and the connection is closed. =item loglevel = noise|trace|debug|info|notice|warn|error|critical Set the logging level. Connection established messages are logged at level C, notable errors are logged with C. Default is C. =item mtu = bytes Sets the maximum MTU that should be used on outgoing packets (basically the MTU of the outgoing interface) The daemon will automatically calculate maximum overhead (e.g. UDP header size, encryption blocksize...) and pass this information to the C script. Recommended values are 1500 (ethernet), 1492 (pppoe), 1472 (pptp). This value must be the minimum of the MTU values of all nodes. =item nfmark = integer This advanced option, when set to a nonzero value (default: C<0>), tries to set the netfilter mark (or fwmark) value on all sockets gvpe uses to send packets. This can be used to make gvpe use a different set of routing rules. For example, on GNU/Linux, the C could set C to 1000 and then put all routing rules into table C<99> and then use an ip rule to make gvpe traffic avoid that routing table, in effect routing normal traffic via gvpe and gvpe traffic via the normal system routing tables: ip rule add not fwmark 1000 lookup 99 =item node = nickname Not really a config setting but introduces a node section. The nickname is used to select the right configuration section and must be passed as an argument to the gvpe daemon. =item node-up = relative-or-absolute-path Sets a command (default: none) that should be called whenever a connection is established (even on rekeying operations). Note that node-up/down scripts will be run asynchronously, but execution is serialised, so there will only ever be one such script running. In addition to all the variables passed to C scripts, the following environment variables will be set (values are just examples): =over 4 =item DESTNODE=branch2 The name of the remote node. =item DESTID=2 The node id of the remote node. =item DESTSI=rawip/88.99.77.55:0 The "socket info" of the target node, protocol dependent but usually in the format protocol/ip:port. =item DESTIP=188.13.66.8 The numerical IP address of the remote node (gvpe accepts connections from everywhere, as long as the other node can authenticate itself). =item DESTPORT=655 # deprecated The protocol port used by the other side, if applicable. =item STATE=up Node-up scripts get called with STATE=up, node-change scripts get called with STATE=change and node-down scripts get called with STATE=down. =back Here is a nontrivial example that uses nsupdate to update the name => ip mapping in some DNS zone: #!/bin/sh { echo update delete $DESTNODE.lowttl.example.net. a echo update add $DESTNODE.lowttl.example.net. 1 in a $DESTIP echo } | nsupdate -d -k $CONFBASE:key.example.net. =item node-change = relative-or-absolute-path Same as C, but gets called whenever something about a connection changes (such as the source IP address). =item node-down = relative-or-absolute-path Same as C, but gets called whenever a connection is lost. =item pid-file = path The path to the pid file to check and create (default: C). =item private-key = relative-path-to-key Sets the path (relative to the config directory) to the private key (default: C). This is a printf format string so every C<%> must be doubled. A single C<%s> is replaced by the hostname, so you could use paths like C to fetch the files at the location where C puts them. Since only the private key file of the current node is used and the private key file should be kept secret per-node to avoid spoofing, it is not recommended to use this feature. =item rekey = seconds Sets the rekeying interval in seconds (default: C<3607>). Connections are reestablished every C seconds, making them use a new encryption key. =item seed-device = path The random device used to initially and regularly seed the random number generator (default: F). Randomness is of paramount importance to the security of the algorithms used in gvpe. On program start and every seed-interval, gvpe will read 64 octets. Setting this path to the empty string will disable this functionality completely (the underlying crypto library will likely look for entropy sources on it's own though, so not all is lost). =item seed-interval = seconds The number of seconds between reseeds of the random number generator (default: C<3613>). A value of C<0> disables this regular reseeding. =back =head2 NODE SPECIFIC SETTINGS The following settings are node-specific, that is, every node can have different settings, even within the same gvpe instance. Settings that are set before the first node section set the defaults, settings that are set within a node section only apply to the given node. =over 4 =item allow-direct = nodename Allow direct connections to this node. See C for more info. =item compress = yes|true|on | no|false|off For the current node, this specified whether it will accept compressed packets, and for all other nodes, this specifies whether to try to compress data packets sent to this node (default: C). Compression is really cheap even on slow computers, has no size overhead at all and will only be used when the other side supports compression, so enabling this is often a good idea. =item connect = ondemand | never | always | disabled Sets the connect mode (default: C). It can be C (always try to establish and keep a connection to the given node), C (never initiate a connection to the given host, but accept connections), C (try to establish a connection when there are outstanding packets in the queue and take it down after the keepalive interval) or C (node is bad, don't talk to it). Routers will automatically be forced to C unless they are C, to ensure all nodes can talk to each other. =item deny-direct = nodename | * Deny direct connections to the specified node (or all nodes when C<*> is given). Only one node can be specified, but you can use multiple C and C statements. This only makes sense in networks with routers, as routers are required for indirect connections. Sometimes, a node cannot reach some other nodes for reasons of network connectivity. For example, a node behind a firewall that only allows connections to/from a single other node in the network. In this case one should specify C and C (the other node I be a router for this to work). The algorithm to check whether a connection may be direct is as follows: 1. Other node mentioned in an C? If yes, allow the connection. 2. Other node mentioned in a C? If yes, deny direct connections. 3. Allow the connection. That is, C takes precedence over C. The check is done in both directions, i.e. both nodes must allow a direct connection before one is attempted, so you only need to specify connect limitations on one node. =item dns-domain = domain-suffix The DNS domain suffix that points to the DNS tunnel server for this node. The domain must point to a NS record that points to the I, i.e. dns-domainname = tunnel.example.net dns-hostname = tunnel-server.example.net Corresponds to the following DNS entries in the C domain: tunnel.example.net. NS tunnel-server.example.net. tunnel-server.example.net. A 13.13.13.13 =item dns-hostname = hostname/ip The address to bind the DNS tunnel socket to, similar to the C, but for the DNS tunnel protocol only. Default: C<0.0.0.0>, but that might change. =item dns-port = port-number The port to bind the DNS tunnel socket to. Must be C<53> on DNS tunnel servers. =item enable-dns = yes|true|on | no|false|off See gvpe.protocol(7) for a description of the DNS transport protocol. Avoid this protocol if you can. Enable the DNS tunneling protocol on this node, either as server or as client. Support for this transport protocol is only available when gvpe was compiled using the C<--enable-dns> option. =item enable-icmp = yes|true|on | no|false|off See gvpe.protocol(7) for a description of the ICMP transport protocol. Enable the ICMP transport using ICMP packets of type C on this node. =item enable-rawip = yes|true|on | no|false|off See gvpe.protocol(7) for a description of the RAW IP transport protocol. Enable the RAW IPv4 transport using the C protocol (default: C). =item enable-tcp = yes|true|on | no|false|off See gvpe.protocol(7) for a description of the TCP transport protocol. Enable the TCPv4 transport using the C port (default: C). Support for this transport protocol is only available when gvpe was compiled using the C<--enable-tcp> option. =item enable-udp = yes|true|on | no|false|off See gvpe.protocol(7) for a description of the UDP transport protocol. Enable the UDPv4 transport using the C port (default: C). =item hostname = hostname | ip [can not be defaulted] Forces the address of this node to be set to the given DNS hostname or IP address. It will be resolved before each connect request, so dyndns should work fine. If this setting is not specified and a router is available, then the router will be queried for the address of this node. Otherwise, the connection attempt will fail. Note that DNS resolving is done synchronously, pausing the daemon. If that is an issue you need to specify IP addresses. =item icmp-type = integer Sets the type value to be used for outgoing (and incoming) packets sent via the ICMP transport. The default is C<0> (which is C, also known as "ping-reply"). Other useful values include C<8> (C, a.k.a. "ping") and C<11> (C), but any 8-bit value can be used. =item if-up-data = value The value specified using this directive will be passed to the C script in the environment variable C. =item inherit-tos = yes|true|on | no|false|off Whether to inherit the TOS settings of packets sent to the tunnel when sending packets to this node (default: C). If set to C then outgoing tunnel packets will have the same TOS setting as the packets sent to the tunnel device, which is usually what you want. =item max-retry = positive-number The maximum interval in seconds (default: C<3600>, one hour) between retries to establish a connection to this node. When a connection cannot be established, gvpe uses exponential back-off capped at this value. It's sometimes useful to set this to a much lower value (e.g. C<120>) on connections to routers that usually are stable but sometimes are down, to assure quick reconnections even after longer downtimes. =item max-ttl = seconds Expire packets that couldn't be sent after this many seconds (default: C<60>). Gvpe will normally queue packets for a node without an active connection, in the hope of establishing a connection soon. This value specifies the maximum lifetime a packet will stay in the queue, if a packet gets older, it will be thrown away. =item max-queue = positive-number>=1 The maximum number of packets that will be queued (default: C<512>) for this node. If more packets are sent then earlier packets will be expired. See C, above. =item router-priority = 0 | 1 | positive-number>=2 Sets the router priority of the given node (default: C<0>, disabled). If some node tries to connect to another node but it doesn't have a hostname, it asks a router node for it's IP address. The router node chosen is the one with the highest priority larger than C<1> that is currently reachable. This is called a I connection, as the connection itself will still be direct, but it uses another node to mediate between the two nodes. The value C<0> disables routing, that means if the node receives a packet not for itself it will not forward it but instead drop it. The special value C<1> allows other hosts to route through the router host, but they will never route through it by default (i.e. the config file of another node needs to specify a router priority higher than one to choose such a node for routing). The idea behind this is that some hosts can, if required, bump the C setting to higher than C<1> in their local config to route through specific hosts. If C is C<0>, then routing will be refused, so C<1> serves as a "enable, but do not use by default" switch. Nodes with C set to C<2> or higher will always be forced to C = C (unless they are C). =item tcp-port = port-number Similar to C (default: C<655>), but sets the TCP port number. =item udp-port = port-number Sets the port number used by the UDP protocol (default: C<655>, not officially assigned by IANA!). =back =head1 CONFIG DIRECTORY LAYOUT The default (or recommended) directory layout for the config directory is: =over 4 =item gvpe.conf The config file. =item if-up The if-up script =item node-up, node-down If used the node up or node-down scripts. =item hostkey The private key (taken from C) of the current host. =item pubkey/nodename The public keys of the other nodes, one file per node. =back =head1 SEE ALSO gvpe(5), gvpe(8), gvpectrl(8). =head1 AUTHOR Marc Lehmann